Grid Director 4200 Installation Manual
63
includes eight fans with fan speed control; fan speed is dynamically controlled as a function of
temperature.
LED indications provide an onsite report on the operating conditions of the air cooling system
modules, and provide an alarm indicator in the event of a high temperature condition.
Figure 19: sFU-42H Horizontal Fan Unit
Refer to LED Indications for a comprehensive list of LEDs, LED description and
functionality.
To replace the sFU-42H Horizontal Fan Unit:
1. Loosen the four screws that secure the sFU-42H Horizontal Fan Unit to the chassis.
2. Remove the sFU-42H Horizontal Fan Unit by sliding it out of the chassis.
3. Replace with a new sFU-42H Horizontal Fan Unit and tighten the four screws (within five
minutes).
4. Listen for proper fan operation and check the LEDs.
Chapter 8