Grid Director 4200 Installation Manual
33
Indication
LED Description
Remarks
Off- All fan drawer are OK
On - Horizontal fan units fault indication. Indicates
that at least one of the eight fans has failed.
PS (Orange)
AC-DC power supply fault indication.
Indicates that at least one of the main AC-DC power
supplies has an AC or DC fault.
Off- All PSUs OK
ON- Fault
5.17 sPSU-S Power Supply LEDs
Table 23: sPSU-S LEDs
Indication
Description
DC ON (Green)
ON Indicates that the DC power source is present.
AC ON (Green)
ON Indicates that the AC power source is present.
5.18 Environmental Specifications
The following table details the environment specifications for the Grid Director 4200.
Table 24: Grid Director 4200 Environmental Specifications
Ambient Operating Temperature
32° to 113°F (0° to 45°C)
Operating Humidity
15 to 80%, non-condensing
Operating Altitude
0 to 9843 ft (3000m)
Storage Temperature
-13° to 158°F (-25° to +70°C)
Storage Humidity
5 to 90% non-condensing
Storage Altitude
0 to 15,000 ft (4570m)
5.19 Acoustic Data
Acoustic noise is reported in accordance with ISO 7779 [ECMA 74] standard.
5.20 Reliability (MTBF)
The Mean Time between Failures (MTBF) for individual switch components is shown in the
tables below. These figures indicate the mean elapsed time until a single component fails in the
module, whether or not that failure impacts the operation of the switch. Note that in many
cases redundant modules can be configured, which dramatically increases the overall system
Mean Time between Critical Failures (MTBCF).